CPBI (5814-xxx)
Jumpers Connectors Memory Pin Assigments



5814tdc

Jumpers


NOTE:
For two-position jumpers (3-post), "LEFT" is toward the bracket end of the board; "RIGHT" is toward the connectors.

* = default value



JU1/JU2 SYSTEM FLASH ROM OPERATIONAL MODES
The Flash ROM has two programmable sections: the Boot Block for "flashing" in the BIOS and the Main Block for the executable BIOS and PnP parameters. Normally only the Main Block is updated when a new BIOS is flashed into the system.
JU1 JU2
Program All (Boot and Main) Right Left
Normal PnP (Program Main Block) Right * Right *
Write Protect Left Right



JU3 CMOS CLEAR
INSTALL = Clear CMOS
REMOVE = Operate *

NOTE: The CMOS Clear jumper works on power-up. To clear the CMOS, power down the system, install the jumper, then turn the power back on. CMOS is cleared during the POST routines. Then power down the system again and remove the jumper before the next power-up.



JU4 PASSWORD CLEAR
INSTALL = Reset to null
REMOVE = Normal operation *



JU5 SCSI TERMINATION ENABLE
INSTALL= Enable on-board active termination for SCSI interface *
REMOVE= Disable




JU6 WATCHDOG TIMER
BOTTOM = Normal reset *
TOP = Enable watchdog



JU7 FAN SPEED MONITOR
INSTALL = Enable processor fan monitor
REMOVE = Disable *



ETHERNET LEDS AND CONNECTORS
The Ethernet interface has two LEDs for status indication and an RJ-45 network connector.
LED/Connector Description
Link/Activity LED Green LED which indicates the link status.
Off = The Ethernet interface did not find a valid link on the network connection. Transmit and receive are not possible.
On =
(solid)
The Ethernet interface has a valid link on the network connection and is ready for normal operation. The Speed LED identifies connection speed.
On =
(flashing)
Indicates network transmit or receive activity.
Speed LED Amber LED which identifies connection speed.
Off = Indicates a 10Mb/s connection.
On = Indicates a 100Mb/s connection.
RJ-45 Network Connector The RJ-45 network connector requires a category 5 (CAT5) unshielded twisted-pair (UTP) 2-pair cable for a 100-Mb/s network connection or a category 3 (CAT3) or higher UTP 2-pair cable for a 10-Mb/s network connection.


Connectors


NOTE:
Pin 1 on the connectors is indicated by the square pad on the PCB.



J6 - PROCESSOR FAN
3 pin single row header, Molex #22-23-2031
PIN SIGNAL
1 Gnd
2 +12V
3 FanTach



J7 - PCI EIDE OR COMPACT FLASH CONNECTOR
40 pin dual row header, 3M #30340-6002HB
PIN SIGNAL
1 Reset
3 Data 7
5 Data 6
7 Data 5
9 Data 4
11 Data 3
13 Data 2
15 Data 1
17 Data 0
19 Gnd
21 DRQ 0
23 IOW
25 IOR
27 IORDY
29 DACK 0
31 IRQ 14
33 Add 1
35 Add 0
37 CS 1P
39 IDEACTP
PIN SIGNAL
2 Gnd
4 Data 8
6 Data 9
8 Data 10
10 Data 11
12 Data 12
14 Data 13
16 Data 14
18 Data 15
20 NC
22 Gnd
24 Gnd
26 Gnd
28 SELPDP
30 Gnd
32 NC
34 Gnd
36 Add 2
38 CS 3P
40 Gnd



J8 - COMPACT FLASH POWER
2 pin header, Amp #640456-2
PIN SIGNAL
1 Gnd
2 +3.3V




P1 - PCI 10/100BASE-T ETHERNET CONNECTOR
8 pin shielded RJ-45 connector, Molex #43202-8110
PIN SIGNAL
1 TD+
2 TD-
3 RX+
4 NC
5 NC
6 RX-
7 NC
8 NC




P2 - PCI 10/100BASE-T ETHERNET CONNECTOR
8 pin shielded RJ-45 connector, Molex #43202-8110
PIN SIGNAL
1 TD+
2 TD-
3 RX+
4 NC
5 NC
6 RX-
7 NC
8 NC




P3 - UNIVERSAL SERIAL BUS (USB0) CONNECTOR
Right angle single port, Amp #787616-1 (+5V fused with self-resetting fuses)
PIN SIGNAL
1 +5V - USB0
2 USB0-
3 USB0+
4 Gnd - USB0




P4 - PCI SVGA INTERFACE CONNECTOR
15 pin VGA connector, Amp #748390-5
   
PIN SIGNAL
   
1 Red
   
2 Green
   
3 Blue
   
4 NC
   
5 Gnd
PIN SIGNAL
   
6 Gnd
   
7 Gnd
   
8 Gnd
   
9 NC
   
10 Gnd
   
PIN SIGNAL
   
11 NC
   
12 EEDI
   
13 HSYNC
   
14 VSYNC
   
15 EECS



P5 - COM1/COM2 CONNECTORS
Dual 9 pin D, Amp #750593-4

Pin-out for each 9 pin D is as follows:
PIN SIGNAL
1 Carrier Detect
2 Receive Data-I
3 Transmit Data-0
4 Data Terminal Ready-0
5 Signal Gnd
PIN SIGNAL
6 Data Set Ready-I
7 Request to Send-O
8 Clear to Send-I
9 Ring Indicator-I




P6 - KEYBOARD/MOUSE CONNECTOR
Stacked dual 6 pin right angle mini DIN, Amp #440173-3

Keyboard Connector:
PIN SIGNAL
1 Kbd Data
2 Reserved
3 Gnd
4 Kbd Power (+5V fused) with self-resetting fuse
5 Kbd Clock
6 Reserved



PS/2 Mouse Connector:
PIN SIGNAL
1 Ms Data
2 Reserved
3 Gnd
4 Kbd Power (+5V fused) with self-resetting fuse
5 Ms Clock
6 Reserved




P7 - PARALLEL PORT CONNECTOR
25 pin D, Amp #747846-4
PIN SIGNAL
1 Strobe
2 Data Bit 0
3 Data Bit 1
4 Data Bit 2
5 Data Bit 3
6 Data Bit 4
7 Data Bit 5
8 Data Bit 6
9 Data Bit 7
10 ACK
11 Busy
12 Paper End
13 Slct
PIN SIGNAL
14 Auto Feed XT
15 Error
16 Init
17 Slct In
18 Gnd
19 Gnd
20 Gnd
21 Gnd
22 Gnd
23 Gnd
24 Gnd
25 Gnd





Memory


The DRAM interface consists of two dual in-line memory module (DIMM) sockets and supports auto detection of memory up to 512MB of Synchronous DRAM (SDRAM). Minimum memory size is 8MB. The System BIOS automatically detects memory type, size and speed.

The SBC uses industry standard 64-bit or 72-bit wide gold finger DIMM DRAM in two 168-pin DIMM sockets.

NOTE: Memory can be installed in one or both DIMM sockets. If only one DIMM module is used, it must be populated in Bank 0 (BK0) if it is an 8MB or 16MB DIMM module; single DIMMs of all other sizes must be populated in Bank 1 (BK1). If two modules are used, they must be the same DIMM type, but may be different sizes (see table below). EDO DIMMs are not supported. All DIMMs must have gold contacts.

The SBC supports DIMM memory modules which are PC-100 compliant and have the following features:

  • 168-pin DIMMs with gold-plated contacts
  • 100MHz SDRAM
  • Non-ECC (64-bit) or ECC (72-bit) memory
  • 3.3 volt only
  • Single or double-sided DIMMs in the sizes listed below
  • Buffered or Registered configuration
DIMM Size DIMM Type Non-ECC ECC
8 MB Unbuffered 1M x 64 1M x 72
16 MB Unbuffered 2M x 64 2M x 72
32 MB Unbuffered 4M x 64 4M x 72
64 MB Unbuffered 8M x 64 8M x 72
128 MB Unbuffered 16M x 64 16M x 72
256 MB Registered
or Unbuffered
32M x 64 32M x 72


NOTE: DIMM modules must not exceed 1.2" in height.
256MB unbuffered DIMMs must be based on 128Mbit SDRAM chips.

All memory components and DIMMs used with the SBC must be PC-100 compliant, which means that they comply with Intel's PC SDRAM specifications. These include the PC SDRAM Specification (memory component specific), the PC Unbuffered DIMM Specification, the PC Registered DIMM Specification and the PC Serial Presence Detect Specification.

PIN ASSIGNMENTS


J1 and J2 comprise the 32-bit/33MHz CompactPCI Bus as defined by the CompactPCI Specification.

Connectors J3, J4 and J5 of the CompactPCI Bus are utilized by the SBC for connection to the Rear Transition Module (RTM). The SBC and RTM are designed so that the signals on J3, J4 and J5 must be routed only through those connectors between the SBC and RTM. No other connection of those signals should be made on the backplane. Specifically, this SBC must not be used in conjunction with a backplane that has signals on J3, J4 or J5 bussed to the SBC slot, i.e., some H.110 backplanes.

The pin assignments for the J3, J4 and J5 connectors are defined in the tables below.

NOTE: rJ3, rJ4 and rJ5 are designations used on the RTM10.


J3/rJ3

PIN   F E D C B A
19   GND   SIRQ SIORDY   SRESET
18   GND SDACK#     CSIP# CS3P#
17   GND SDREQ SDD12 SDD13 SDD14 SDD15
16   GND   SDD8 SDD9 SDD10 SDD11
15   GND   SDA2 VCC SDA1 SDA0
14   GND SDIOW# SDD4 SDD5 SDD6 SDD7
13   GND SDIOR# SDD0 SDD1 SDD2 SDD3
12   GND WDATA# INDEX# MTR0# DRVDEN1 DRV0#
11   GND RDATA# DRVDEN0 MTR1# DSKCHG DRV1#
10   GND STEP# TRKO# DIR# HDSEL# WP#
9   GND USB+ BUSY AFD# ERR# WGATE#
8   GND USB- STB# VCC SLIN# PE
7   GND INIT# PPD4 PPD5 PPD6 PPD7
6   GND ACK# PPD0 PPD1 PPD2 PPD3
5   GND SLCT KBDATA SPKR MSDATA  
4   GND RXDI KBCLK VCC MSCLK PBRST#
3   GND TXD1 DCD1 DSR1 RTS1 CTS1
2   GND RXD2 DTR1 RI1 DTR2 RI2
1   GND TXD2 DCD2 DSR2 RTS2 CTS2




J4/rJ4

PIN   F E D C B A
25   GND          
24   GND          
23   GND          
22   GND          
21   GND          
20   GND          
19   GND          
18   GND          
17   GND          
16   GND          
15   GND          
14  
13 KEY
12  
11   GND MON_FAN2 MON_CI     MON_RST#
10   GND MON_FAN1 MON_GPO      
9   GND          
8   GND          
7   GND   PIRQ PIORDY   PRESET
6   GND PDACK#     CS1P# CS3P#
5   GND PDREQ PDD12 PDD13 PDD14 PDD15
4   GND   PDD8 PDD9 PDD10 PDD11
3   GND   PDA2   PDA1 PDA0
2   GND PDIOR# PDD4 PDD5 PDD6 PDD7
1   GND PSIOW# PDD0 PDD1 PDD2 PDD3




J5/rJ5

PIN   F E D C B A
22   GND SPDLED1 GND LAN1RX- GND LAN1TX+
21   GND ACTLED1 GND LAN1RX+ GND LAN1TX-
20   GND LNKLED1 GND GND GND GND
19   GND SPDLED2 GND LAN2RX- GND LAN2TX+
18   GND ACTLED2 GND LAN2RX+ GND LAN2TX-
17   GND LNKLED2 GND GND GND GND
16   GND TRMPWR SCD#15 SCD#14 SCD#13 SCD#12
15   GND TRMPWR SCD15 SCD14 SCD13 SCD12
14   GND TRMPWR SCD#2 SCD#1 SCD#0 SCDPH#
13   GND TRMPWR SCD2 SCD1 SCD0 SCDPH
12   GND TRMPWR SCD#6 SCD#5 SCD#4 SCD#3
11   GND TRMPWR SCD6 SCD5 SCD4 SCD3
10   GND SCLED# GND SCATN# SCDPL# SCD#7
9   GND DIFSENSE GND SCATN SCDPL SCD7
8   GND VGASCK GND SCRST# SCACK# SCBSY#
7   GND VGASDA GND SCRST SCACK SCBSY
6   GND HSYNC GND SCCD# SCSEL# SCMSG#
5   GND VSYNC GND SCCD SCSEL SCMSG
4   GND GND GND SCD#8 SCIO# SCREQ#
3   GND RED GND SCD8 SCIO SCREQ
2   GND GREEN GND SCD#11 SCD#10 SCD#9
1   GND BLUE GND SCD11 SCD10 SCD9



* Intel and Pentium are registered trademarks and Celeron is a trademark of Intel Corporation.
All other product names are trademarks of their respective owners.

 

PICMG Single board Computer and Passive Backplane source
Copyright © 2007 Trenton Technology Inc.
Last Updated 6/1/04

CatalogSingle Board ComputersBackplanesCompactPCILinksTechnical Support RequestTerms of UsePrivacy